 Small project "LPG solenoid controller"

 Controller provides additional convenience and safety in LPG usage on the boat.

Functions:

  • Provide sparkless switching  solenoid power.
  • Protects solenoid circuit in case of cable damage (short or open circuit). 
  • Limit continuous current  over solenoid to prevent solenoid coil extensive heating and significantly decrease  power consumption during LPG usage.
  • Limit solenoid open valve time  (60 min).
  • LPG Solenoid is controlled by single button with LED.
  • Can be used with LPG gas sensors to cut gas supply if leakage happen. 

  

Hardware design files link

 

Normal operation

Indicator:

  • Off  - no power provided to controller.
  • Low brightness, short blink one a 2sec  - solenoid circuit OK, LPG solenoid closed.
  • 1 seconds ON, 1 sec OFF - solenoid activated > 10 minutes to auto-shutoff.
  • Fast blinking < 10 minutes to auto-shutoff.
  • 3 short blinks, then 5 sec on - solenoid activated  24 hour timer (not recommended)
    Errors indication 
  • Quick blinking 1 sec - OFF one sec - Solenoid circuit problem (check wires). 

 Button functions: 

  • Short press <1sec  - Toggle solenoid On /Off or restart timer (when timeout is soon)
  • Press and  hold (for a second) - switch solenoid off.

 

Controller is ready for installation.


 

 


 